本人毕业后被分配到吉林吉诺尔电器集团公司,售后服务部门工作至今。我的工作主要包括冰箱,冰柜维修,空调器的安装与维修。例:冰箱(吉诺尔208型)通电后,压缩机启动运转正常,但是不制冷,冷藏室内能听见毛细管过气的声音,判断为无制冷剂,因为208型内部为铝管机构,初步判断为下蒸发器泄露,将压缩机的低压管路切割后,给蒸发器打压,压力表打到10个压后拧紧,2个小时后压力下降到7个压,说明蒸发器有泄露处,把冰箱背板拆开,打开保温层,取下蒸发器,换上铜管的蒸发器后,给蒸发器和冷凝器同时打压检漏,无泄露后,做好保温层,背板压好后,抽真空加氟,运转正常,制冷。空调(春兰1P壁挂式分体空调),室内制冷机开机后,只有风吹出,不制冷,由于室内温度高于设置温度, 查看外机风扇运转,但压缩机不启动,断电后将机外壳打开,用外用表检查压缩机和压缩机启动电容,最后测定启动电容容量,换同等容量的电容器后试机。压缩机启动,室内机制冷正常。海尔1.5P壁挂式空调,开机后制冷差,查看外机阀门外有油泥,挂表测压后,加氟后,制冷正常,将有油泥外的外机阀门拧紧,用泡沫水家查证明无泄露后,维修完毕。

I graduated from the electrical company was assigned to the Jilin Jinuoer, after-sale services sector to date. I work mainly refrigerators, ice-blocks maintenance, installation and maintenance of air conditioners. Cases : refrigerators (Jinuoer 208), electric, compressor start functioning normally, but not refrigeration, cold storage room to hear a capillary gas voices judged as a refrigerant, since 208 for Lu:guan internal organs, the initial judgment of the evaporator leaking, compressor cutting low voltage lines, to the evaporator pressure, pressure gauge hit 10 postponed screw tight, two hours after the pressure dropped to seven pressure on the vaporizer is leaking Department, refrigerators buildings disconnected, open heat preservation layer down evaporator, into the brass evaporator, the evaporator condensers and at the same time suppressing leakage, without disclosing, a heat preservation layer, the huge pressure well, pumping vacuum plus fluorine, normal functioning, refrigeration. AC (cymbidium 1P wall hanging type air-conditioning sub-groups), indoor plant switch on the machine, only the wind out, not refrigeration, indoor temperature higher than a temperature check, the fans running, but not activated compressors, power will be the case opened, with external table inspection compressors and compressor start capacitance, and finally start capacitance measurement capacity, for the same capacity condenser after ban plane. Compressors activated indoor mechanism cold normal. Haier 1.5P wall hanging air-conditioning, refrigeration, poor switch on the machine to check the plane, a grease valves, wall charts 1,117,000, plus fluorine, refrigeration normal, there will be grease outside of the valves screw tight, with no evidence of the bubble leaking water home after repairs

好,来了
After myself graduate am assigned to the Jilin lucky lake electric appliance group company, post-sale service department work until now. My work mainly includes the refrigerator, the refrigerator service, the air-conditioner installment and the service. Example: After the refrigerator (lucky lake 208) the circular telegram, the compressor starts the revolution to be normal, but does not refrigerate, the cold-storageroom internal energy hears the capillary vessel the sound which was mad, judges for does not have the refrigerant, because 208 interior are the aluminum tube organizations, the preliminary judgment for under evaporator revelation, after compressor low pressure pipeline cutting, hits to the evaporator the pressure, after the pressure gauge projects on 10 pressures to screw tight, after 2 hours the drop of pressure to 7 pressures, showed the evaporator has the revelation place, disassembles the refrigerator back board, opens the heat insulating layer, takes down the evaporator, after exchanges the copper pipe the evaporator, simultaneously hits for the evaporator and the condenser presses the leak detection, after does not have the revelation, completes the heat insulating layer, the back boardAfter presses, pulls out the vacuum to add the fluorine, the revolution is normal, refrigeration. Air conditioning (cymbidium virens 1P wall hanging type fission air conditioning), after in room refrigerator starting, only then the wind blows out, does not refrigerate, because the indoor temperature is higher than the establishment temperature outside, examines machine the ventilator revolution, but the compressor does not start, after the power failure machine the outer covering will open, will start the electric capacity with the external use table inspection compressor and the compressor, finally will determine the start electric capacity capacity, after will trade the same level capacity the capacitor the testing. The compressor starts, in the room machine the refrigeration is normal. Haire the 1.5P wall hanging type air conditioning, after starting refrigerates the difference, outside examined machine outside the valve has the greasy dirt, after hangs the table to measure presses, after adds the fluorine, the refrigeration is normal, will have outside the greasy dirt outside machine valve to screw tight, after froth Shui Jiacha proved will not have the revelation, the service finished.